INSTRUCTION MANUAL FOR WIRE WELDING MACHINE
IMPORTANT:
BEFORE STARTING THE EQUIPMENT,
READ THE CONTENTS OF THIS MANUAL, WHICH
MUST BE STORED IN A PLACE FAMILIAR TO ALL
USERS FOR THE ENTIRE OPERATIVE LIFE-SPAN OF
THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WELD-
ING OPERATIONS.
1 SAFETY PRECAUTIONS
WELDING AND ARC CUTTING CAN BE HARMFUL TO
YOURSELF AND OTHERS. The user must therefore be
educated against the hazards, summarized below, deriv-
ing from welding operations. For more detailed informa-
tion, order the manual code 3.300.758
ELECTRIC SHOCK - May be fatal.
• Install and earth the welding machine according
to the applicable regulations.
• Do not touch live electrical parts or electrodes
with bare skin, gloves or wet clothing.
• Isolate yourselves from both the earth and the work-
piece.
• Make sure your working position is safe.
FUMES AND GASES - May be hazardous to your health.
• Keep your head away from fumes.
• Work in the presence of adequate ventilation,
and use ventilators around the arc to prevent
gases from forming in the work area.
ARC RAYS - May injure the eyes and burn the skin.
• Protect your eyes with welding masks fitted with
filtered lenses, and protect your body with appro-
priate safety garments.
• Protect others by installing adequate shields or cur-
tains.
RISK OF FIRE AND BURNS
• Sparks (sprays) may cause fires and burn the
skin; you should therefore make sure there are no
flammable materials in the area, and wear appro-
priate protective garments.
NOISE
This machine does not directly produce noise
exceeding 80dB. The plasma cutting/welding pro-
cedure may produce noise levels beyond said
limit; users must therefore implement all precautions
required by law.
PACEMAKERS
• The magnetic fields created by high currents may affect
the operation of pacemakers. Wearers of vital electronic
equipment (pacemakers) should consult their physician
before beginning any arc welding, cutting, gouging or
spot welding operations.
EXPLOSIONS
• Do not weld in the vicinity of containers under pres-
sure, or in the presence of explosive dust, gases or
fumes. · All cylinders and pressure regulators used in
welding operations should be handled with care.
ELECTROMAGNETIC COMPATIBILITY
This machine is manufactured in compliance with the
instructions contained in the harmonized standard IEC
60974-10, and must be used solely for professional
purposes in an industrial environment. There may be
potential difficulties in ensuring electromagnetic
compatibility in non-industrial environments.
IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL.
2 GENERAL DESCRIPTIONS
2.1 SPECIFICATIONS
This welding machine is a power source developed with
inverter technology, suitable for MIG, TIG and MMA weld-
ing.
This welding machine must not be used to defrost pipes.
2.2 EXPLANATION OF TECHNICAL SPECIFICATIONS
IEC 60974.1-5-7-10 The welding machine is manufac-
tured according to these international stan-
dards.
N°.
Serial number. Must be indicated on any
request regarding the welding machine.
Single-phase
3 ~
f
1
f
2
frequency converter.
MIG Suitable for MIG-MAG welding.
MMA Suitable for welding with covered eletrodes.
TIG Suitable for TIG welding.
U0.
Secondary open-circuit voltage.
X.
Duty cycle percentage. The duty cycle
expresses the percentage of 10 minutes
during which the welding machine may run
at a certain current without overheating.
I2.
Welding current
U2.
Secondary voltage with current I2
U1.
Rated supply voltage
1~ 50/60Hz 50- or 60-Hz single-phase power supply.
I1 Max
Max. absorbed current at the corresponding
current I2 and voltage U2.
I1 eff
This is the maximum value of the actual
current absorbed, considering the duty cycle.
This value usually corresponds to the capaci-
ty of the fuse (delayed type) to be used as a
protection for the equipment.
IP23.
Protection rating for the housing.
Grade 3 as the second digit means that this
equipment is suitable for use outdoors in the
rain.
Suitable for use in high-risk environments.
S
NOTE: The welding machine has also been designed for
use in environments with a pollution rating of 3.
(See IEC 60664).
static
transformer-rectifier
7