Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher HDS 13/20-4 S Originalbetriebsanleitung Seite 34

Vorschau ausblenden Andere Handbücher für HDS 13/20-4 S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Burner error symbol
– The exhaust temperature limiter has
been triggered.
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
– Error occurs repeatedly.
 Inform Customer Service.
Error symbol
– Leak in the high pressure system
 Check high pressure system and con-
nections for tightness.
 Inform Customer Service.
Flame sensor symbol
– The flame sensor turned the burner off.
 Inform Customer Service.
System care detection symbol
– System care detection defective
 Inform Customer Service.
System care symbol
Note: Burner can operate 5 more hours.
– System care bottle empty.
 Replace the system care bottle.
34
Note: Burner operation no longer possible.
– System care bottle empty.
 Replace the system care bottle.
Appliance is not running
– No power
 Check power connection/conduit.
Device is not building up pressure
– Air within the system
Vent pump:
 Set dosing value for detergent to "0".
 With open hand spray gun turn device
on and off multiple times with the device
switch.
 Open and close the pressure/quantity
regulation at the pump unit with the
hand spray gun open.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
 If detergent tank is empty, refill.
 Check connections and conduits.
– Pressure is set to MIN
 Set pressure to MAX.
– Sieve in the water connection is dirty
 Clean sieve.
 Clean the fine filter; replace it, if neces-
sary.
– Amount of water supply is too low.
 Check water supply level (refer to tech-
nical data).
Device leaks, water drips from the
bottom of the device
– Pump leaky
Note: 3 drops/minute are allowed.
 With stronger leak, have device
checked by customer service.
Device turns on and off while hand
spray gun is closed
– Leak in the high pressure system
 Check high pressure system and con-
nections for tightness.
– 12
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hds 13/20-4 sx

Inhaltsverzeichnis