BAE IO-Link Sensor Amplifier
6.10
errors and warnings
If an error occurs, a flashing error message is
output on the display. The error message
disappears once the error is eliminated.
error mes-
Possible cause
sage
Switching stage
E r r out p
must carry an
excessive
current. Load is
switched off or
limited.
Sensor not
E r r i npt
connected or
defective
Feedback and warnings for advanced
functions (during teach-in)
With advanced functions (teach functions), error-
free execution is indicated through a brief flashing
of the value/selection range and the calculated
values are applied.
12
english
7
The sensor amplifier has an IO-Link communica-
tion interface that requires an IO-Link master for
operation. The IO-Link interface enables direct
access to sensor values and parameters and
offers the option to parameterize the device
Troubleshooting
during running operation.
Connect a
You can find the IODDs required to configure the
permissible load
IO-Link device, as well as detailed information on
(see technical
sensor
data on
parameters at www.balluff.com.
page 16).
7.1
• SIO mode
Check sensor
• Block parameterization
and connection
and exchange if
• Data storage
necessary.
• Supported profile: Smart Sensor
IO-Link
values,
diagnosis
information,
Features
and