Herunterladen Inhalt Inhalt Diese Seite drucken

SCAN 58-1 Montageanleitung Und Bedienungsanleitung Seite 10

Inhaltsverzeichnis

Werbung

10
Scan 58-2 Wandmodell & Scan 58-5 Wandmodell
(schmalen Seitengläsern)
Scan 58-2 Wall + Scan 58-5 Wall
Wall mounted room heater fired by solid fuel
Standard:
EN 13240
Minimum distance to combustible materials:
Side: 600 mm - Front: 1000 mm
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
EUR
Intermittent
Klasse 2
SINTEF 110-0298
Norway
Schweiz
LRV 11
VKF
Germany
BStV
1
FSPS-Wa 1769-EN
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
Scan 58-3 Wandmodell & Scan 58-6 Wandmodell
(breite seitengläsern)
Scan 58-3 Wall + Scan 58-6 Wall
Wall mounted room heater fired by solid fuel
Standard:
EN 13240
Minimum distance to combustible materials:
Side: 600 mm - Front: 1000 mm
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
EUR
Intermittent
Klasse 2
SINTEF 110-0298
Norway
Schweiz
LRV 11
VKF
Germany
BStV
1
FSPS-Wa 1769-EN
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
T E C N I S C H E D AT E N
EC no. 90358612
0,11%
1334 mg/Nm³
44 mg/Nm³
350°C
5,5 kW
76%
Wood
Intermittent
Approved by
EN 13240
RWE Power AG
SINTEF - NBL
N 18900
RWE Power AG
RWE Power AG
09-2011
EC no. 90358613
0,11%
1334 mg/Nm³
44 mg/Nm³
350°C
5,5 kW
76%
Wood
Intermittent
Approved by
EN 13240
RWE Power AG
SINTEF - NBL
N 18900
RWE Power AG
RWE Power AG
09-2011
Scan 58-7 & Scan 58-8
Scan 58-7 + Scan 58-8
Freestanding room heater fired by solid fuel
Standard:
EN 13240
Minimum distance to combustible materials:
Side: 350 mm - Back: 250 mm - Front: 1000 mm
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
EUR
Intermittent
EN 13240
Klasse 2
SINTEF 110-0298
Norway
Schweiz
LRV 11
VKF
Germany
BStV
1
FSPS-Wa 2053-EN
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
Scan 58-7 & Scan 58-8 mit High Top
Scan 58-7 + Scan 58-8 with high top
Freestanding room heater fired by solid fuel
Standard:
EN 13240
Minimum distance to combustible materials:
Side: 350 mm - Back: 250 mm - Front: 1000 mm
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
EUR
Intermittent
EN 13240
Klasse 2
SINTEF 110-0298
Norway
15 a B-VG
Austria
Schweiz
LRV 11
VKF
Germany
BStV
1
FSPS-Wa 2053-EN
Angaben für Österreich
Wärmeleistungsbereich:
Brennstoffwärmeleistung:
Zulässige Brennstoffe:
Prüfbericht:
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
EC no. 90358609
0,07%
875 mg/Nm³
16 mg/Nm³
365°C
5,5 kW
75%
Wood
Intermittent
Approved by
RWE Power AG
SINTEF - NBL
RWE Power AG
RWE Power AG
09-2011
EC no. 90358619
0,07%
875 mg/Nm³
16 mg/Nm³
280°C
5,5 kW
82%
Wood
Intermittent
Approved by
RWE Power AG
SINTEF - NBL
RWE Power AG
RWE Power AG
RWE Power AG
3,0 - 6,7 kW
8,4 kW
Scheitholz
FSPS-Wa 2053-A
09-2011