  • DEUTSCH, seite 1
Before each use
Check connection cable for damages
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer
service person/ electrician.
Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.
Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
Weekly
Check oil level Please contact Custom-
er Service immediately if the oil is milky
(water in oil).
Clean water filter.
Clean filter at the detergent suck hose.
monthly or after 500 operating
hours
Oil change.
Oil change
Note
See "Technical Details" for details of oil
quantity and type.
Unscrew the oil drain screws at the bot-
tom of the motor casing.
Drain the oil in a collection basin.
Screw in the oil drain screws and tight-
en them.
Fill in new oil slowly; air bubbles should
go out.
Attach the lid of the oil container.
Fasten the device hood.

Troubleshooting

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Get the electrical components checked and
repaired only by authorised customer serv-
ice persons.
Contact an authorised customer service
person in case of problems not mentioned
in this chapter or if you are in doubt or when
you have been explicitly asked to do so.
Appliance is not running
Check connection cable for damages.
Check the supply voltage.
Engine is overheated (control lamp is il-
luminated).
Let the appliance cool down if the motor
is over-heated. Then switch it on again.
Call Customer Service in case of elec-
trical defects.
Pressure does not build up in the
appliance
Clean water filter.
Clean high-pressure nozzle.
Replace high-pressure nozzle.
Deaerate the appliance (see "Start-up")
Check water supply level (refer to tech-
nical data).
Check all inlet pipes to the pump.
Top up detergent orset dosing value for
detergent to "0".
Contact Customer Service if needed.
Pump leaky
3 drops per minute are permitted and can
come out from the lower side of the appli-
ance. Call Customer Service if there is
heavy leakage.
With stronger leak, have device
checked by customer service.