Installation of the control

Housing design and connection overview

1
Microfuse T6,3A
2
Weather station, WG bus, manual key and motion detector
3
Channel 1
4
Mains supply 230 volt (L/N/PE)
5
Channel 2 (starting from version WS1-2)
6
Channel 3 (starting from version WS1-3)
7
Channel 4 (starting from version WS1-4)
8
Constant voltage 230 Volt
9
Multifunctional relay for alarm, heating or cooling system
(1 potential-free closer)
The unit operates with 230 V AC voltage 50 Hz, the rated input depends on the
number and performance of the connected motors. Each output must be loaded
with a maximum of 400 Watt. However, the total connected load must not
exceed approx. 1.6 KW. The output voltage amounts to 230 VAC.