7 Storage, transport, installation altitude

7 Lagerung, Transport, Aufstellhöhe
 Sliders are to be stored and transported only in the plastic containers (with cardboard inlay)
provided for this purpose, or already installed and secured in LinMot P stators.
 Remove the slider from this plastic containers only for assembling.
 The storage area must be dry, dust-free, frost-free and vibration-free.
 The relative air humidity should be less than 60 %.
 Prescribed storage temperature: -15 °C...70 °C
 The motor must be protected against extreme weather conditions.
 The air in the storage area must not contain any harmful gases.
 The max. installation altitude is 4'000 m above sea level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
 LinMot Läufer dürfen ausschliesslich in der Orginalverpackung transportiert und gelagert
werden.
 Die Läufer sollten erst beim Einbau aus der Verpackung genommen werden.
 Der Lagerraum muss trocken, staubfrei, frostfrei und erschütterungsfrei sein.
 Die relative Luftfeuchte sollte weniger als 60 % betragen.
 Vorgeschriebene Lagertemperatur: -15 °C...70 °C
 Der Motor muss vor extremen Witterungen geschützt werden.
 Die Raumluft darf keine aggressiven Gase enthalten.
 Die maximale Aufstellhöhe beträgt 4'000 m ü. M.
Ab 1'000 m ist bei Luftkühlung ein Derating von 1 °C pro 100 m zu berücksichtigen.