Maintenance schedule
After the work
Warning
Risk of damage. Do not wash down the ap-
pliance with water and do not use aggres-
sive detergents.
Drain off dirt water.
Remove the lid of the wastewater reser-
voir and wash the inside of the lid and
the float with water.
Rinse the dirt water tank with clear water.
Remove and clean the suction bar (see
"Maintenance Procedures").
Clean the outside of the appliance with
a damp cloth which has been soaked in
mild detergent.
Clean the vacuum lips, check for wear
and replace them if required.
Check the brush for wear and replace if
required (see "Maintenance tasks").
Charge battery if required.
Weekly
Clean the fresh water filter.
Monthly
Check battery pole for oxidation; brush
it if required and lubricate it using pole
grease. Ensure that the connection ca-
ble sits firmly.
Check the condition of the seals be-
tween dirt water reservoir and cover, re-
place if required.
Yearly
Have the prescribed inspection carried
out by the customer service.
Maintenance Works
Dismantling the vacuum bar
1 Suction hose
2 Vacuum bar
3 Cross handle for fastening of vacuum bar
Pull off the suction hose.
Loosen cross-handles.
Remove the vacuum bar.
Turn or replace vacuum lips
Remove the vacuum bar.
1 Wing nut
2 Vacuum lip
Unscrew the wing nuts.
Reverse or replace the vacuum lips.
Note
Do not transpose the front and rear vacuum
lips.
Reassemble the suction bar in the re-
verse sequence.
– 6
EN
21