Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Performance - TermaTech TT30S Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Declaration of Performance

Product:
Product type/application:
Type:
Fuel:
Productions no.
Manufacturer:
Certification and requirements:
AVCP system:
European standard:
Certification:
Declared performance:
Essential characteristics
Reaction to fire
Distance to combustible materials TT30 + TT30S:
Emission of combustion products
Risk of burning fuel falling out
Surface temperature
Clean ability
Mechanical strength
Emission of hazardous materials
Flue gas temperature
Output
Energy efficiency
The undersigned is responsible for the manufacturing and conformity with the declared performance.
14.03.2016
Room heater burning solid fuel without hot water supply
TT30: S01-700/701 TT30S: S01-720/721 TT30G: S01-710/711
Wood
Please see nameplate on the back of the oven
TermaTech A/S
Gunnar Clausens Vej 36
8260 Viby J
Denmark
System 3
EN 13240:2001/AC:2006 + EN13240:2001/A2:2004/AC:2007
Rhein-Ruhr Feuerstätten Prüfstelle GmbH, notified body no. 1625, has
performed determination of the
basis of type testing and issued test report no.RRF-40 15 4171
AI
Rear:
Sides:
TT30G:
Rear:
Sides:
Other safety distances – please see User
and mounting manual
CO = 0,07 %
NOx = 107 mg/m³
THC = 75 mg/m³
PM = 17 mg/m³
Passed
Passed
Passed
Passed
Passed
273° Celsius
5 KW
81 %
Søren Toft______________________________
E-mail:
info@termatech.com
Web:
www.termatech.com
Tel.:
+45 8742 0035
product type and declared performance on the
Performance
min. 100 mm
min. 250 mm
min. 100 mm
min. 490 mm
Harmonised technical
specification
DS/EN
13240:2001
A2:2004 / AC:2007
/
31