Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Performance - TermaTech TT22 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Declaration of Performance

TT22-CPR-2016-Version2
Product:
Product type/application:
Type:
Fuel:
Productions no.
Manufacturer:
Certification and requirements:
AVCP system:
European standard:
Certification:
Declared performance:
Essential characteristics
Reaction to fire
Distance to combustible materials Rear: min. 150 mm
Emission of combustion products
Risk of burning fuel falling out
Surface temperature
Clean ability
Mechanical strength
Emission of hazardous materials
Flue gas temperature
Output
Energy efficiency
The undersigned is responsible for the manufacturing and conformity with the declared performance.
1.9.2016
Room heater burning solid fuel without hot water supply
TT22: S01-640/641, TT22S: S01-642/643, TT22H: S01-644/645,
TT22HS: S01-646/647, TT22R: S01-648/649 TT22HST: S01-650/651
TT22RP: S01-654
Wood
Please see nameplate on the back of the oven
TermaTech A/S
Gunnar Clausens Vej 36
8260 Viby J
Denmark
System 3
DS/EN 13240:2001 + A2:2004
Teknologisk Institut,
notified body no. 1235, has performed determination of
the
product type and declared performance on the basis of type testing and
issued test report no. 300-ELAB-1778-EN-Rev-1.
AI
Sides: min. 450 mm
Other safety distances – please see User
and mounting manual
CO = 0,07 %
NOx = 101 mg/m³
OGC = 95 mgC/Nm³
PM = 14 mg/m³
Passed
Passed
Passed
Passed
Passed
259° Celsius
7,5 KW
82 %
Søren Toft______________________________
E-mail:
info@termatech.com
Web:
www.termatech.com
Tel.:
+45 8742 0035
Performance
Harmonised technical
specification
DS/EN 13240:2001 +
A2:2004
31

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tt22rTt22hTt22sTt22hsTt22hstTt22rp

Inhaltsverzeichnis