Declaration of Performance

TT22-CPR-2016-Version2
Product:
Product type/application:
Type:
Fuel:
Productions no.
Manufacturer:
Certification and requirements:
AVCP system:
European standard:
Certification:
Declared performance:
Essential characteristics
Reaction to fire
Distance to combustible materials Rear: min. 150 mm
Emission of combustion products
Risk of burning fuel falling out
Surface temperature
Clean ability
Mechanical strength
Emission of hazardous materials
Flue gas temperature
Output
Energy efficiency
The undersigned is responsible for the manufacturing and conformity with the declared performance.
1.9.2016
32
Room heater burning solid fuel without hot water supply
TT22: S01-640/641, TT22S: S01-642/643, TT22H: S01-644/645,
TT22HS: S01-646/647, TT22R: S01-648/649 TT22HST: S01-650/651
Wood
Please see nameplate on the back of the oven
TermaTech A/S
Gunnar Clausens Vej 36
8260 Viby J
Denmark
System 3
DS/EN 13240:2001 + A2:2004
Teknologisk Institut,
notified body no. 1235, has performed determination of
the
product type and declared performance on the basis of type testing and
issued test report no. 300-ELAB-1778-EN-Rev-1.
AI
Sides: min. 450 mm
Other safety distances – please see User
and mounting manual
CO = 0,07 %
NOx = 101 mg/m³
THC = 95 mg/m³
PM = 14 mg/m³
Passed
Passed
Passed
Passed
Passed
259° Celsius
7,5 KW
82 %
Søren Toft______________________________
E-mail:
info@termatech.com
Web:
www.termatech.com
Tel.:
+45 8742 0035
Performance