Maintenance
TIRES
Tire selection can affect the stability of the machine.
Use only tires supplied by UpRight unless approved
by the manufacturer in writing
BATTERY CHARGING
Charge batteries only in a well ventilated area.
Hazard of explosive gas mixture. Keep
sparks, flame and smoking materials away
from batteries.
Always wear safety glasses when working
with batteries.
Battery fluid is highly corrosive. Rinse away
any spilled fluid thoroughly with clean water.
Always replace batteries with UpRight
batteries or manufacturer approved replace-
ments weighing 120 lbs. each.
Charge batteries as follows:
1. Check the batteries fluid level. If the electrolyte
level is lower than
3
plates, add clean, distilled water only.
2. Verify charger voltage switch is set to the correct
voltage.
3. Connect extension cord (minimum 12 gauge
(1.5 mm²) conductor and maximum 50 ft. (15 m)
in length) to charger plug located through the
opening in front of the chassis (see figure 7).
Connect extension cord to properly grounded
outlet of proper voltage and frequency.
4. The charger will turn on automatically.
5. When the batteries are fully charged, the charger
will turn off automatically .
Ammeter
Figure 7: Battery Charger
/
in. (10 mm) above the
8
AC Cord

BATTERY MAINTENANCE

Check battery fluid level daily, especially if work
platform is being used in a warm, dry climate.
If electrolyte level is lower than
plates add distilled water only. DO NOT use tap
water it will shorten battery life.
Keep terminals and top of battery clean.

HYDRAULIC OIL

1. Check oil level at sight gauge inside engine
compartment right hand side with the platform
fully lowered.
2. If necessary, fill to capacity with clean ISO 46
compatible hydraulic oil.
3. Lift flap located on top of chassis right side
(see figure 7).
4. Open filler / breather cap to add hydraulic oil.
5. Replace cap.
LUBRICATION
Refer to service manual for lubrication chart and
guidelines.
Figure 8: Batteries (Typical Both Sides)
Figure 9: Hydraulic Oil Filler / Breather Cap and Oil
Level Sight Gauge
9
3
/
in. (10 mm) above
8
Battery Disconnect
Hydraulic Oil Filler / Breather Cap
Oil Level Sight Gauge