Rectifying malfunctions

Malfunction
Water jet too weak
No flush actuation
Water runs continuously Technical fault
Unwanted flow of water,
either too soon or
delayed
Water drips from the tap
housing
Red LED flashes during
flush actuation
Skilled persons will find further information on troubleshooting on the website of the respective Geberit sales
company.
2011761803 © 09-2016
967.455.00.0 (00)
Cause
Tap aerator contaminated
Basket filter blocked
Pipe pressure too low
Pipe pressure too low
Network failure
Batteries dead or rechargeable battery
empty
Technical fault
IR window is dirty or wet
IR window scratched
Detection distance of the infrared
sensor not set correctly
Technical fault
Batteries almost dead or rechargeable
battery almost empty
Rectification
4 Clean the tap aerator. → see
"Cleaning the tap aerator", page 19
4 Clean the basket filter. → see
"Cleaning the basket filter", page 19
4 Contact a skilled person.
4 Contact a skilled person.
4 Check the power supply.
4 Replace batteries or charge
rechargeable battery for generator
operation. → see "Replacing the
batteries", page 20, and "Checking
and charging the rechargeable battery
for generator operation", page 20
4 Contact a skilled person.
4 Shut off water supply and contact a
skilled person.
4 Clean or dry the IR window.
4 Contact a skilled person.
4 Contact a skilled person.
4 Shut off water supply and contact a
skilled person.
4 Replace batteries or charge
rechargeable battery for generator
operation. → see "Replacing the
batteries", page 20, and "Checking
and charging the rechargeable battery
for generator operation", page 20
EN
17