Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Transport; Care And Maintenance; Maintenance Intervals - Kärcher HDS-E 8/16-4M Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
CAUTION
Risk of personal injury or damage! Consid-
er the weight of the appliance when storing
it.

Transport

Figure 6
ATTENTION
Risk of damage! When loading the appli-
ance with a forklift, observe the illustration.
ATTENTION
Protect the trigger from damage during
transport.
CAUTION
Risk of personal injury or damage! Mind the
weight of the appliance during transport.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Care and maintenance

DANGER
Risk of injury by inadvertent start-up of ap-
pliance and electric shock. Prior to all work
on the appliance, switch off the appliance
and pull the power plug.
 Shut off water supply.
 Open the hand spray gun.
 Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
 Close the hand spray gun.
 Set the appliance switch to "0/OFF".
 Pull main plug out of socket with dry
hands only.
 Remove water connection.
 Activate hand spray gun until device is
pressure less.
 Secure the trigger gun. To do so, push
the safety catch towards the front.
 Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.
26

Storage

Maintenance intervals

Weekly
 Clean the sieve in the water connection.
 Clean the fine filter.
 Check oil level.
ATTENTION
Risk of damage! In case of lacteous oil in-
form Kärcher customer service immediate-
ly.
Monthly
 Clean the sieve in the safety block.
 Clean filter at the detergent suck hose.
After 400 operating hours, at least
annually
 Check the calcification degree of the
boiler and consider having it cleaned by
customer service.
Every 500 operating hours, at least
annually
 Oil change.
 Have the maintenance of the device
performed by the customer service.

Maintenance Works

Clean the sieve in the water connection
 Take out sieve.
 Clean sieve in water and reinstall.
Cleaning the fine filter
 Unpressurize the appliance.
 Unscrew the fine filter from the boiler.
 Remove the fine filter and the filter in-
sert.
 Clean the filter with clean water or com-
pressed air.
 Reinstall in reverse sequence.
Clean the sieve in the safety block
 Loosen covering nut and take off hose.
 Take out sieve.
Note: If necessary turn in screw M8 appr. 5
mm inwards and therewith pull out sieve.
 Clean sieve in water.
 Push sieve inwards.
 Put on hose.
 Tighten covering nut firmly.
– 8
EN

Werbung

Inhaltsverzeichnis
loading