Herunterladen Inhalt Inhalt Diese Seite drucken

Software Update; Software Update Using; Online Software Update; Faults - Bosch KTS 340 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für KTS 340:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.6

Software update

The software update is either performed using the
"ESI[tronic] Startcenter" DVD or "Online".
i
The online help for the software update can be
found in the ESI[tronic] Startcenter software under
"Help >> Help".
5.6.1
Software update using ESI[tronic] DVD
1.
Insert the "
ESI[tronic] Startcenter" DVD in the
DVD drive (e. g. "D:\") of the PC/Laptop.
2.
Open the "
Execute" input box (select "Start >>
Execute..." in the task bar).
D:\setup.exe
3.
Enter
?
Set-up is started.
?
Follow the installation instructions on the screen.
4.
Re-start the computer on completion of installation.
?
Windows is shut down and the ESI[tronic] Start-
center re-started.
5.
Use the USB connecting cable to connect the
KTS 340 to a PC/Laptop.
6.
Use the power supply unit provided to supply the
KTS 340 with voltage.
?
The KTS 340 starts up.
!
The USB link and the power supply to the KTS 340
must not be interrupted during the software update.
7.
ESI[tronic] Startcenter: Open "
information".
8.
Select available update.
9.
Select <
Update>.
"
The system software is installed on the KTS 340.
Robert Bosch GmbH
and confirm with <O�>.
��S ��� >> Device
Operation | ��S ��� | 27
5.6.2
Online software update (as of ESI[tronic]
Startcenter version 2��9/2)
Start the "
1.
ESI[tronic] Startcenter".
2.
Open the "
Settings >> Online updates" input box.
3.
Enter customer number and password and select
<Continue>.
i
If "
Login" is not possible, check proxy settings under
"Settings >> User settings".
4.
Select available update and start software update.
5.
Follow the installation instructions on the screen.
Re-start the computer on completion of installation.
6.
?
Windows is shut down and the ESI[tronic] Start-
center re-started.
7.
Use the USB connecting cable to connect the
KTS 340 to a PC/Laptop.
Use the power supply unit provided to supply the
8.
KTS 340 with voltage.
?
The KTS 340 starts up.
!
The USB link and the power supply to the KTS 340
must not be interrupted during the software update.
9.
ESI[tronic] Startcenter: Open "
information".
10.
Select available update.
11.
Select <
Update>.
"
The system software is installed on the KTS 340.
5.7

Faults

No communication with the control unit
The fault message "No system found" appears during
control unit diagnosis.
Possible causes
Possible remedies
Wrong cable
Check whether the correct
connected.
cable has been used.
Wrong pin selected in
Consult "Diagnostic socket"
pin selection menu.
to see which pin has to be
used.
i
If problems of a different nature occur, please
contact the ESI[tronic] service hotline directly.
��S ��� | 27