Battery Removal/Installation - Hitachi WR 14DSL Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
English
2. Long Socket
Form B
L1
H
L2
L
Square
head drive
Part Name
dimensions S
(mm)
12 mm
13 mm
14 mm
17 mm
17 mm
12.7
Long
19 mm
Socket
19 mm
21 mm
21 mm
21 mm
22 mm
24 mm
3. Extension bar: Code No. 873633
The extension bar is convenient for working in very restricted spaces or
when the socket provided cannot reach the bolt to be tightened.
CAUTION:
When the extension bar is used, the tightening torque is reduced slightly
compared with the ordinary socket.
4. Universal joint: Code No. 992610
The universal joint is convenient for impacting nuts when there is an angle
between the socket and wrench, or when working in a very narrow space.
5. Duct Socket
This is used for tightening bolts and nuts on flange sections of air
conditioners, type ducts, etc.
Code No.
993658
992613
992615
9
Form C
L1
S
H
Suitable Bolt Diameter
Code No.
High
ISO
tension
(ordinary)
955138
955139
M8
955140
955141
M10
955149
M10
955142
M12
955150
M12
955143
955151
991480
955144
M12
M14
955146
M16
Hexagonal width across flats (mm)
12
13
14
L2
S
L
Hexagonal width
across flats H
ISO
Inch
(mm)
(small)
bolts
M8
W5/16"
12
13
M10
14
M12
W3/8"
17
M12
W3/8"
17
M14
W7/16"
19
M14
W7/16"
19
W1/2"
21
W1/2"
21
W1/2"
21
M16
22
M18
24
6. Corner attachment (Model EW-14R)
Use this attachment only when the machine is applied to the nut or bolt at
the right angle.
7. Bit adaptor: Code No. 322752
This is used for tightening small screws (M6 – M8).
NOTE:
(1) This adaptor is set only on the anvil (drive angle) of the main unit. The bit
adapter cannot be attached to the special accessory anvil (square drive).
(2) Before starting work with the adapter, tighten a few screws with it to make
sure it's tightening with the appropriate torque.
(3) Tightening speed will be greatly reduced when driving wood, tapping or
other similar screws.
Optional accessories are subject to change without notice.
APPLICATION
Tightening and loosening of all types of bolts and nuts, used for securing
structural items.

BATTERY REMOVAL/INSTALLATION

1. Battery removal
Hold the handle tightly and push the battery latch to remove the battery (see
Figs. 1 and 2).
CAUTION:
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see Fig. 2).
Form D
L1
H
L2
L
Main Socket
Dimensions (mm)
Form
L
L1
L2
B
52
20
34
B
52
20
34
B
52
20
34
B
52
24
34
B
75
24
57
B
52
24
34
B
75
24
57
D
52
24
34
D
75
24
57
D
125
24
107
D
52
24
34
D
52
25
34
S
Table 2
øF
20
21.5
22
25
25
28
28
31
31
31
32.5
34

Werbung