10. MEASUREMENT OPERATION

Never exceed the maximum permissible input values. Do not touch any
circuitry or circuit components whose voltage may be greater than 30 V/ACrms
or 42 V/AC (peak) or 60 V/DC! Risk of fatal injury!
The maximum permissible voltage in the circuit against ground potential may
not exceed 600 V in CAT II or 300 V in CAT III.
Always check all connected test leads for damages (i.e. cuts, tears or pinching)
before measuring. Cease use of damaged test leads immediately! Risk of fatal
injury!
Do not touch beyond the feelable handle markings on the test leads during
measurement.
Only connect the two test leads required for measuring to the device. For
safety reasons, remove all unnecessary test leads from the device when
measuring the current.
Measurements of circuits >30 V/AC AND >60 V/DC may be carried out by
professionals and persons familiar with the applicable regulations for the
measurement and all possible hazards arising therefrom.
For your own safety, observe all relevant safety instructions, regulations and
safety measures.
Measurements are shown on the digital clamp multimeter's LCD (5). The digital clamp
multimeter's measurement display comprises 2000 counts (count = lowest display value). For
negative values, the polarity is displayed automatically with the sign (-).
You have exceeded the measuring range when the display shows < OL > (short for
overload).
There are protective transport caps in the included test leads' angled plugs. Remove
them before inserting the plugs into the test sockets.