Operation
Installing the communication DTM in FieldCare
Before the configuration of the device can be done, FieldCare Device Setup must be installed
on your PC. The installation instructions can be found in the FieldCare instructions.
Subsequently, install the FieldCare device driver according to the following instructions:
1.
Firstly, install the device driver "CDI DTMlibrary" in FieldCare. It can be found under
"Endress+Hauser Device DTMs → Service / Specific → CDI" in FieldCare.
2.
Then the DTM catalog must be updated. Add the new installed DTMs to the DTM
catalog.
Installing the Windows driver for the TXU10/FXA291
To install the Windows driver Administrator rights are required. Proceed as follows:
1.
Connect the device to the PC using the TXU10/FXA291 interface adapter.
 A new device is detected and the Windows installation assistant opens.
2.
In the installation assistant, do not carry out the automatic search for a driver. For this,
choose "No, not this time" and click "Next".
3.
In the subsequent window, choose "Install from a list or specific location" and click "Next".
4.
In the next window, click "Browse" and select the directory where the driver for the
TXU10/FXA291 adapter is located.
 The driver is installed.
5.
Finish the installation by clicking "Finish".
6.
A further device is detected and the Windows installation assistant opens once more.
Again, choose "No, not this time" and click "Next".
7.
In the subsequent window, choose "Install from a list or specific location" and click "Next".
8.
In the next window, click "Browse" and select the directory where the driver for the
TXU10/FXA291 adapter is located.
 The driver is installed.
9.
Finish the installation by clicking "Finish".
The installation of the Windows driver for the interface adapter is now complete. Which
COM-Port has been assigned for the adapter can be seen in the Windows device manager.
Establishing the connection
To establish the connection with FieldCare, proceed as follows:
1.
Firstly, edit the connection macro. For this, start a new project and in the window
displayed, click with the right mouse button on the symbol for "Service (CDI) FXA291"
and choose "Edit".
2.
In the following window, next to "Serial interface", select the COM port which has been
assigned during the installation of the Windows driver for the TXU10/FXA291 adapter.
 The macro is now configured. Complete configuration by clicking "Finish".