Herunterladen Diese Seite drucken

Installation Instructions - Truma Trumatic S 3002 P Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Trumatic S 3002 P:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation instructions

1. Remove heating case:
Up to year of manufacture 05/96: Take hold at the bottom,
draw forwards, and then lift upwards.
From year of manufacture 05/96: Draw the top forwards,
press the retaining springs on the sides upwards, and fold the
casing forwards.
2. Detach the ignition cable (1) from the push ignitor.
3. Lay the ignition cable on the base plate (possibly with
a short loop) to the automatic ignitor in such a way that it
cannot come in contact with the heat exchanger (2) or the
exhaust gas pipe (3).
4. Using the pressure rod (4), rotate the safety pilot valve (5) to
the "Open" position, and then withdraw the bar.
Up to year of manufacture 02/92: Remove the two screws
and the retaining clamp at the ignition safety valve (5) and re-
move the cover.
8
From year of manufacture 02/92: Use a screwdriver to
bend back the three retaining clips at the ignition safety val-
ve (5) and remove the cover.
5. Use a knife, saw, or side-cutting pliers to cut an opening in
the cover for passing the cable through.
6. Lay the microswitch (7) with the connection cable (8) into
the ignition safety valve (5) in such a way that the spring of
the contact points towards the rotation ring (retaining pins
integrated in the housing).
7. Screw or press the cover back on again. Insert the pressure
rod and turn the safety pilot valve back to the "0" position.

Quicklinks ausblenden:

Werbung