The drain screw is opened by turning it counter-clockwise (when look-
ing at the screw on the bottom of the compressor) so that the conden-
sate can be completely drained out of the pressure vessel. Then close
the drain screw again (turn clockwise). Check the pressure vessel for
rust and damage each time before use.
The compressor shall not be operated if the pressure vessel is dam-
aged or rusty.
If you discover damage, please contact the customer service workshop.
10.3 Safety valve (Fig. 2)
The safety valve (12) has been set for the highest permitted pressure
of the pressure vessel. It is not permitted to adjust the safety valve or
remove the connection lock (12.2) between the exhaust nut (12.1) and
its cap (12.3).
Actuate the safety valve every 30 operating hours but at least 3 times
a year, to ensure that it works when required. Turn the perforated ex-
haust nut (12.1) counterclockwise to open it and use your hands to
pull the valve rod outwards over the perforated exhaust nut (12.1) to
open the safety valve outlet. Now, the valve audibly releases air. Then,
tighten the exhaust nut clockwise again.
10.4 Storage (fig. 3)
m Important!
Disconnect the device from the mains outlet and wind up the mains
cable (9) on the cable holder (4). Vent the device and all connected
compressed air tools. Store the compressor in such a way that it can-
not be used by unauthorised persons.
m Important!
Store the compressor only in a dry location which is not accessible to
unauthorized persons. Always store upright, never tilted!