13. Troubleshooting

Fault
The compressor does
not start.
Compressor runs, but
no pressure.
Compressor running,
pressure shown on
the manometer, but
tools are not running.
Possible cause
Mains voltage not present.
Mains voltage too low.
Outdoor temperature too low.
Motor is overheated.
Non-return valve leaking.
The seals are damaged.
Drain screw for condensate leaking.
Hose connections leaking.
Quick-coupler leaking.
Pressure set too low at pressure
regulator.
www.scheppach.com
Remedy
Check cable, mains plug, fuse and socket.
Avoid extension cables that are too long. Use
extension cables with sufficient conductor
cross-section.
Do not operate at outside temperatures below
0° C.
Let the motor cool down, if necessary, eliminate
the cause of overheating.
Replace the non-return valve.
Check the seals and have any damaged seals
replaced by a service centre.
Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
Check compressed air hose and tools, replace
if necessary.
Check quick coupling, replace if necessary.
Turn up the pressure regulator further.