15. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
The compressor does
not start.
Compressor runs, but
no pressure.
Compressor running,
pressure shown on the
manometer, but tools
are not running.
28 | GB
Possible cause
Mains voltage not present.
Mains voltage too low.
Outdoor temperature too low.
Motor is overheated.
The safety valve leaks.
The seals are damaged.
Drain screw for condensate leaking.
Hose connections leaking.
Quick-coupler leaking.
Pressure set too low at pressure
regulator.
www.scheppach.com
• If the manufacturer delivers a new electrical device
to a private household, the manufacturer can ar-
range for the free collection of the old electrical de-
vice upon request from the end user. Please contact
the manufacturer's customer service for this.
• These statements only apply to devices installed
and sold in the countries of the European Union
and which are subject to the European Directive
2012/19/EU. In countries outside the European Un-
ion, different regulations may apply to the disposal of
waste electrical and electronic equipment.
Remedy
Check cable, mains plug, fuse and socket.
Avoid extension cables that are too long.
Use extension cables with sufficient con-
ductor cross-section.
Do not operate at outside temperatures
below +5°C.
Allow the motor to cool down. If neces-
sary, remedy the cause of the overheating.
Contact your local service centre. Only al-
low qualified personnel to carry out repairs.
Check the seals and have any damaged
seals replaced by a service centre.
Tighten the screw by hand. Check the seal
on the screw and replace if necessary.
Check compressed air hose and tools,
replace if necessary.
Contact your local service centre. Only allow
qualified personnel to carry out repairs.
Turn up the pressure regulator further.