When drilling metal, you may have to cool the drill bit
with suitable fluid.
11.9 Working with the laser (Fig. 16)
1.
Switch the laser light on with the laser On/Off
switch (25).
2.
Place the marked hole in the fixed point (B) of the
laser.
3.
Put the drill in and drill a hole.
11.10 Countersinking and centre drilling
You can also use this tabletop drill for countersinking
or centre drilling.
Note that countersinking must be performed at the
lowest speed while a high speed is required for centre
drilling.
11.11 Machining wood
Note that suitable dust extraction must be used when
machining wood, as wood dust can be harmful to
health.
Wear a suitable dust protection mask when performing
work that generates dust.
12. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cables
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to insulation damage.
38 | GB
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 volts/50 Hz.
• Extension cables up to 25 m long must have a cross
section of 1.5 square millimetres, and those over
25 m long must have a cross section of at least 2.5
square millimetres.
• The mains power connection is protected with a 16A
slow-blow fuse.
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their rep-
resentative to avoid safety hazards.
13. Transport
1.
To transport the product, disconnect it from the
power supply.
2.
Only lift the product by the belt box and the frame
plate. Never lift the product by the safety devices
or the adjustment handles.
3.
When transporting the product, be aware of the
weight distribution: The product is top-heavy.
Therefore, only transport the machine lying down
and secured on a suitable fixture.
14. Cleaning and maintenance
m WARNING
Have maintenance and repair tasks that are not de-
scribed in this operating manual, carried out by a
specialist workshop. Use only original spare parts.
m WARNING
Improper cleaning or maintenance work can cause
injuries!