4.3 Installing the ventilation system

The ventilation grilles must have an open
cross-section of at least 400cm². This is
achieved by using the Dometic LS 300 absor-
ber ventilation and
which has been tested and approved for this
purpose.
The upper ventilation grille should be posi-
tioned as high as possible above the con-
denser (Fig. 19) .
LS300
Cooling unit /
condenser
Install the lower ventilation grille at floor
level of the vehicle (Fig. 20), allowing unburnt
gas (heavier than air) to escape directly into
the open air. The gas burner must be loca-
ted above the edge (1) .
1
Should this arrangement prove impossible,
a ventilation aperture must be introduced
by the manufacturer of the vehicle into the
recess floor in order to avoid the accumula-
tion of unburnt gas on the floor (Fig. 21).
Ventilation aperture
air extraction system
Fig. 19
Fig. 20
Fig. 21

4.3.1 Position of the ventilation grilles

1.
LS300
LS300
Minimum height of ventilation H
1.
Upper and lower vent grille LS 300
2.
Roof exhaust R500, lower vent grille LS 300
i
Correct mounting of the lower ventilation gril-
le facilitates access to the connections and
functional parts during maintenance.
CAUTION!
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.