Herunterladen Diese Seite drucken

Scope Of Delivery; Installation Set; Spare Filter Cartridge; Technical Data - BWT bestmax X Bedienungsanleitung

Filtersystem zur optimierung von trinkwasser

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
14

1 Scope of delivery

1.1

Installation set

The bestmax installation set comprises the following components (see Fig. 1):
Filter head (1) with internal thread for mounting the filter cartridge (3), suitable for all filter cartridge
 
sizes with installation plate. Integrated into the filter head are an Aquastop and a return valve.
Bracket (2) for mounting the bestmax filter cartridge.
 
Bestmax filter cartridge in sizes X, S, V, M, L, XL an 2XL (3) with hygiene cap and external thread
 
for screwing into the filter head (1).
Installation and operating instructions.
 
In the interest of hygiene, all components are packed in protective film.
1.2

Spare filter cartridge

The spare filter pack contains the spare filter cartridge with hygiene cap (3) packed in
protective film and the installation and operating instructions.

2 Technical data

2.1

Dimensions and weights

bestmax type
Total height without bracket (A)
Total height with bracket (B)
Connection height (C)
Distance from floor (D)
Installation length (E)
Filter cartridges Ø (F)
Weight of filter cartridge, dry (approx.)
Weight of filter cartridge, wet (approx.)
2.2

Operating conditions

bestmax type
Connection thread (intake/outlet)
Nominal flow
Working pressure range
Intake water pressure
Pressure loss at 30 L/h ¹
Pressure loss at 60 L/h ¹
Pressure loss at 180 L/h ¹
Water temperature, min.–max.
Ambient temperature, min.–max.
Ambient temperature during storage/transportation, min.–max.
Bed volume
Operating position
Typical capacity at 10 d°KH for hot drink machines with steam
generation ²
Typical capacity at 10 d°KH for hot drink machines without
steam generation Max. temperature 95°C ²
Chlorine reduction In accordance with Section 5.5.2 EN 14898:2006
¹
At bypass setting "2", with a 1.5 m hose DN8 fitted to both the intake and outlet.
²
The actual capacities in operation can be higher or lower than the capacities stated in the table. The capacities depend on the quality of the input water, the
flow rate, the intake water pressure and the flow continuity. The carbonate hardness reduction is reached in accordance with Section 5.5.5
EN 14898:2006 for the stated capacities.
X
S
mm
270-280
350-360
mm
305
385
mm
226
306
mm
65
65
mm
125
125
mm
88
88
kg
0.5
0.9
kg
1.1
1.5
V
M
L
410-420
465-475
490-502
445
500
527
366
421
448
65
65
65
125
125
125
110
130
147
2.1
2.4
3.4
3.2
4.2
5.9
X
S
V
L/h
bar
bar
bar 0.10 0.10
0.10
0.05
bar 0.15 0.15
0.15
0.15
bar 0.60 0.60
0.50
0.40
°C
+ 4 to + 30
°C
+ 4 to + 40
°C
- 20 to + 40
L
0.45 0.70
1.50
2.00
horizontal oder vertikal
L
600 1.000 2.500 3.800 5.200 6.800 12.000
L
720 1.200 3.000 4.560 6.240 8.160 14.400
Class
1
1
1
XL
2XL
492-502
570-580
527
600
448
520
65
65
125
125
147
185
3.8
7.5
6.0
11.0
M
L
XL
2XL
3/8"
60
2 – 8
> 1.2
0.05
0.10
0.20
0.20
0.15
0.30
0.50
0.50
0.60
2.50
3.10
6.50
1
1
1
1

Werbung

loading