SETTING THE TIMER

A) HOW TO SET THE ON TIME
1. Press the SEL TYPE button once.
The ON and time indications flash.
2. Press the SET H button until the designed
hour is displayed.
Press the SET M button until the designed
minutes are displayed. The display will
EG
change automatically back to show the
present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SEL button to activate
the ON timer.
B) HOW TO SET THE OFF TIME
1. Press the SEL TYPE button twice.
The OFF and time indications flash.
2. Press the SET H button until the designed
hour is displayed.
Press the SET M button until the designed
minutes are displayed. The display will
change automatically back to show the
present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SEL button two times to
activate the OFF timer.
C) HOW TO SET A PROGRAM FOR DAILY
ON/OFF OPERATION (OR VICEVERSA)
1. Set the timer ON/OFF as shown in A) and
B).
2. Press the ON/OFF button to start the air
conditioner.
3. Press three times the TIMER SELECT
button to activate the DAILY timer.
NOTE
After timer setting, press PROGRAM button in order to check the
ON/OFF setting time.

SETTING THE 1 HOUR TIMER

This function causes the unit to operate for one hour at the set
conditions, regardless of whether the unit is on or off.
TIMER SETTING PROCEDURE.
Press four times the TIMER SEL
button.The 1 HOUR TIMER mark will
appear on the display.
CANCELLATION PROCEDURE
• Press the ON/OFF button to turn the air
conditioner off.
• Wait for the indoor unit to stop operating.
• Press the ON/OFF button again to turn
the air conditioner on.

ADJUSTING THE AIR FLOW DIRECTION

HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.
VERTICAL (with remote control unit)
Make sure that the remote control unit has been turned on. Press
the FLAP button to select the sweep function or to choose one of
the six positions of the flap.
Set vertical vanes to the front position during COOLING/DRY
3
operation if humidity is high.
If the vertical vanes are set to the left-most or right-most
position, condensation will form around the air outlet and
drip off.
4
1
2
Do not move the flap with your hands when the air conditioner
is running.
Sweep function
The flap starts moving up and down to deliver air over the
sweep range.
NOTES
• The flap automatically closes when the unit is off.
• During the heating operation, the fan speed will be very low and
the flap will be in the horizontal position (position
being blown out of the unit begins to warm. Once the air warms
up, the flap position and fan speed change to the settings
specified with the remote control.
• Use the FLAP button on the remote control to adjust the
position of the flap. If you move the flap by hand, the factual
flap position and the flap position on the remote control
may no longer match. If this should happen, shut off the
unit, wait for the flap to close, and then turn on the unit
again; the flap position will now be normal again.