7.2.4

Descale the water distributor and spray nozzle

Personnel:
Protective equipment:
Material:
WARNING!
Injuries from uncontrolled chemical spills
Uncontrolled chemical spills can cause serious injuries.
Use the personal protective equipment (PPE) specified in the safety data sheet
for the chemical products.
Requirements:
n
Angle valve for water supply closed.
n
Front hatch open.
n
Product cylinder is removed.
on page 37
3
1
Fig. 13: Remove the water distributor and spray nozzle
Put some Sidosil ® Intensive Rinse Aid in a cup or dish.
1.
2.
Unthread the button
3.
Disconnect the "bypass water"
distributor and remove it.
4.
Unscrew the spray nozzle
5.
Dip the spray nozzle into the limescale remover and let it soak in for two minutes.
6.
Rinse the spray nozzle thoroughly with clean water.
n
Service Personnel
Protective eyewear
n
Chemical resistant protective gloves
n
n
Ecolab Sidosil
Ä Chapter 7.2.2 'Opening the front hatch' on page 36
Ä Chapter 7.2.3 'Remove the product cylinder'
4
5
The liquid should completely cover the spray nozzle.
from the tab on the water distributor
1
3
from the water distributor.
5
Servicing and maintenance
®
Intensive Limescale Remover
Button
1
Water distributor
2
"Bypass water" connection
3
"Spray nozzle" connection
4
Spray nozzle
5
2
and "spray nozzle"
connections from the water
4
39
and remove it.
2