5.2

Hydraulic installation

Connecting the internal water supply
Personnel:
Protective equipment:
Material:
Requirements
n
The unit is mounted in accordance with the regulations.
n
The angle valve is closed.
n
The domestic water pipe (steel flex) is connected to the building's angle valve.
CAUTION!
Damage to the unit if the permissible water pressure is exceeded
– Always observe the max. permissible water pressures and temperatures
(see
If necessary, fit a pressure reducer and/or mixing valve upstream.
– The connection for the water supply (feed line) must be located behind a
shut-off cock (angle valve).
Fig. 4: Connection to domestic water supply
1.
If necessary, remove the protective cap on the connection.
2.
Screw the house water pipe
RTU Dispenser by hand.
n
Service Personnel
n
Qualified employee
n
Protective gloves
n
Safety shoes
n
Protective eyewear
n
House water connection pipe (braided steel)
Ä Section Technical data on page 48 ).
2
1
to the water connection
1
29
Assembly and connection
Domestic water pipe (steel braid)
1
Water connection