DANGER!
Damage and injuries may occur if installation, maintenance or repair
work is carried out incorrectly.
All installation, maintenance and repair work must only be performed by
authorised and trained specialist personnel in accordance with the applicable
local regulations. Safety regulations and prescribed protective clothing when
handling chemicals should be followed. Attention must be paid to the
information included on the product data sheet for the metering medium used.
Prior to all work the feeding of the metering medium should be disconnected
and the system cleaned.
NOTICE!
Only original equipment spare parts may be used for maintenance and
repairs.
CAUTION!
Before maintenance work, the water supply must be interrupted. Furthermore,
the safety guidelines must be observed.
The maintenance interval is 1 year maximum, although every six months is
recommended.
7.1
Maintenance intervals
Interval
Maintenance work
General status:
As required
External dirt:
Check the unit is clean and clean if necessary.
Damage:
Check the unit damage and notify Ecolab Customer Service if necessary.
Product cylinder:
Dirt:
Clean the product cylinder if necessary.
Water supply pipe and water-carrying components in the appliance:
Every six months
Watertightness:
Where necessary. Replace seals or defective components.
Product outlet pipe:
Blockage Watertightness:
Replace the hose if necessary.
Spray nozzle:
Dirt:
Descale and replace if necessary.
Check the flow rate
Every year
Servicing and maintenance
Ä Chapter 2 'Safety' on page 12
35
Personnel
Specialist
Specialist
Specialist
Service personnel
Operator
Specialist
Specialist
Service personnel
Service personnel
MAN054127 Ver. 01-06.2024