Herunterladen Inhalt Inhalt Diese Seite drucken

Details On Energy Consumption; Data Table - STIEBEL ELTRON HSBB 3 S Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für HSBB 3 S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTALLATION
Specification

16.3 Details on energy consumption

Product data complies with EU regulations relating to the Directive on the eco-design of energy related products (ErP).
Manufacturer
Energy efficiency class
Cylinder capacity
Standby losses

16.4 Data table

Power consumption
Max. power consumption, circulation pump on the heat-
ing side
Power consumption, emergency/booster heater
Application limits
Water hardness
pH value (with aluminium compounds)
pH value (without aluminium compounds)
Conductivity (softening)
Conductivity (desalination)
Chloride
Oxygen 8-12 weeks after filling (softening)
Oxygen 8-12 weeks after filling (desalination)
Hydraulic data
Surface area, indirect coil
External available pressure differential at 1.0 m³/h
External available pressure differential at 1.5 m³/h
External available pressure differential at 2 m³/h
External available pressure differential at 2.5 m³/h
Cylinder capacity
Nominal capacity
Energy data
Energy efficiency class
Standby energy consumption/24 h at 65 °C
Electrical data
Rated voltage, controller
Rated voltage, emergency/booster heater
Phases, controller
Phases, emergency/booster heater
MCB/fuse protection, controller
MCB/fuse protection, emergency/booster heater
Versions
Suitable for
Suitable for
IP rating
Dimensions
Height
Width
Depth
Height when tilted
Heat transfer area
Weights
Weight, full
Connections
Connection on the heating side
Cold water connection
DHW connection
46
| HSBB 3
l
W
W
kW
°dH
μS/cm
μS/cm
mg/l
mg/l
mg/l
hPa
hPa
hPa
hPa
l
l
kWh
V
V
A
A
WPL 10 AC(S), WPL 13 E, WPL 15/20/25 AC(S),
mm
mm
mm
mm
kg
HSBB 3
234264
STIEBEL ELTRON
C
168
79
HSBB 3
234264
72
8.8
≤3
8.0-8.5
8.0-10.0
<1000
20-100
<30
<0.02
<0.1
3.3
700
567
374
101
168
168
C
1.9
230
400
1/N/PE
3/N/PE
1 x B 16
3 x B 16
Heat pump
Air | water heat pumps 10 AC(S), 13 E, 15/20/25
WPL 08-22 Trend
IP20
1780
600
650
1810
2.4
332
22 mm
22 mm
22 mm
www.stiebel-eltron.com
HSBB 3 S
234265
STIEBEL ELTRON
C
168
79
HSBB 3 S
234265
72
5.9
≤3
8.0-8.5
8.0-10.0
<1000
20-100
<30
<0.02
<0.1
3.3
700
567
374
101
168
168
C
1.9
230
230
1/N/PE
2/N/PE
1 x B 16
2 x B 16
Heat pump
AC(S), 08-22(S) Trend
IP20
1780
600
650
1810
2.4
332
22 mm
22 mm
22 mm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hsbb 3

Inhaltsverzeichnis