Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Specifications - Lenord, Bauer GEL 3011 Betriebsanleitung

Turmschwingungssensor für safety-anwendungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lenord + Bauer
7

Technical data

7.1

Specifications

General
Measuring axes
Measuring range
Resolution
Accuracy (X, Y)
Temperature dependency
Safety level
Electrical data
Operating voltage
Power consumption
Scanning rate
Digital interfaces
Switched output
Relay
Release criteria (alternatively)
Trigger limits in X direction (+/-)
Trigger limits in Y direction (+/-)
Trigger limit radial
Trigger delay
Inhibit time after relay triggering
Filter
Mechanical data
Housing material
Weight
Dimensions (W×D×H)
Environmental conditions
Assured operating temperature range
Storage temperature range
GEL 3011
Specifications
3 (X, Y, Z); X and Y monitored
-2
± 15 ms
(approx. 1.5g)
-2
± 0.01 ms
-2
± 0.05 ms
at 25 °C
-2
± 0.25 ms
at -40 °C to +85 °C
-2
± 0.004 ms
PLd according to EN ISO 13849
24 VDC ± 10 %
Approx. 2.4 W
5 ms
CANopen
2, each 2 NC and 2 NO, 24 VDC / 0.5 A,
positively driven, floating, position in the
de-energised state and in case of er-
ror: open
Axis related (X, Y) or geometric sum (ra-
dius)
Customized preset
Customized preset
Customized preset
Customized preset (default: 0.05 s)
Customized preset (default: 30 s)
1. Customized preset (default: Butter-
worth 2nd order low-pass filter,
f
= 10 Hz);
C
2. Optional additional filter with custom-
ized characteristics
Aluminium
Approx. 625 g
140 × 60 × 45 mm
-40 °C to +85 °C
-40 °C to +85 °C
7 Technical data
-1
K
41

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis