Herunterladen Inhalt Inhalt Diese Seite drucken

Lenord, Bauer GEL 3011 Betriebsanleitung Seite 35

Turmschwingungssensor für safety-anwendungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lenord + Bauer
First filter
Parameters
Type {Default | Frequency-based low
pass | Coefficient-based}
Default
Frequency-based low pass
Cut-off frequency f
Characteristic {Bessel | Tschebycheff
| Butterworth}
Filter order {1...6}
Coefficient-based
Denominator
Numerator
First trigger characteristic
Parameters
Type {Geometric sum | Axis-related}
Geometric sum
Mean value window
Trigger threshold
Axis-related
Trigger threshold X-
Trigger threshold X+
Trigger threshold Y-
Trigger threshold Y+
Trigger delay
GEL 3011
Safety-related section
(-3dB)
G
Standard
Default
Butterworth 2nd order,
f
= 10 Hz
G
10 Hz
Butterworth
2
Standard
Geometric sum
0.005 s
-2
2 ms
-2
-2 ms
-2
2 ms
-2
-2 ms
-2
2 ms
50 ms
4 Function
Setting
Setting
35