4 Function
Second filter
Parameters
Type {None | Frequency-based low pass
| Coefficient-based}
None (second trigger characteristic not
required)
Frequency-based low pass
Cut-off frequency f
Characteristic {Bessel | Tschebycheff
| Butterworth}
Filter order {1...6}
Coefficient-based
Denominator
Numerator
Second trigger characteristic
Parameters
Type {Geometric sum | Axis-related}
Geometric sum
Mean value window
Trigger threshold
Axis-related
Trigger threshold X-
Trigger threshold X+
Trigger threshold Y-
Trigger threshold Y+
Trigger delay
36
Safety-related section
(-3dB)
G
Standard
Coefficient-based
10 Hz
Butterworth
2
Standard
Geometric sum
0.005 s
-2
2 ms
-2
-2 ms
-2
2 ms
-2
-2 ms
-2
2 ms
50 ms