4 Function
4.1
Safety-related section
4.1.1
Principle
S1
S2
S1
X/Y acceleration sensor
S2
Redundant X/Y acceleration sensor (rotated by 45°)
C1, C2
Filtering, evaluation, control
R1, R2
Relay
Acceleration data
AD
Self-test request
SR
Acceleration data comparison, state, mutual monitoring
AS
Switching command
SC
Feedback
FB
Relay contacts: 2 normally open contacts (safety circuits), 1 normally closed contact
RC
(signalling circuit)
4.1.2
Configuration
The safety-related section is type approved. All function parameters are set in the de-
vice in the factory in accordance with customer requirements; it is not possible for the
customer to change the settings.
General
Parameters
CANopen: LSS support
CANopen: Address {1...126}
Inhibit time after relay triggering
34
Safety-related section
AD
C1
SR
AS
AD
C2
SR
Standard
Yes
1
30 s
SC
R1
FB
SC
R2
FB
Setting
Lenord + Bauer
RC
RC
GEL 3011