Herunterladen Inhalt Inhalt Diese Seite drucken

Limit Position Setting And Programming The First Transmitter; Automatic Setup-Mode, Deletion And Automatic Setting Of The End Positions - Selve Sez-Rc Originalbetriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
iveo initial operation/setting by radio

6.1. Limit position setting and programming the first transmitter

6.1.1. Automatic setup-mode, deletion and automatic setting of the end positions

in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in automatic set-
up-mode. Motor type SEZ-RC will automatically find its stop positions. For this, a motor must
first move against the upper stop and then downwards until it switches off automatically.
Caution! Only connect the radio motor that you wish to program to the mains. It is not possi-
ble to program more than one motor at the same time.
Setting with trans-
mitter
or
Auto-Stop top and
bottom, keep motion
button pressed
1 s
Drive
Connect to power.
Press the UP and DOWN buttons at the transmitter at
the same time. The transmitter is temporarily pro-
grammed into the motor.
The motor moves against the upper stop and stops auto-
matically. The correct direction of rotation assignment
STOP
has been made.
STOP
Continue to keep the button pressed. The motor auto-
matically moves downwards after 1–2 seconds.
Alternatively move the motor downwards using the
DOWN button.
Note: The motor can be moved upwards and down-
wards. As long as the lower end position has not been
found, the downwards moving will be interrupted twice.
The motor will reach the lower limit and stops automati-
cally. The end positions are now set and the rotation
direction assignment is correct. Perform a test run.
Press the PROG button at the transmitter. The transmit-
ter is now permanently programmed.