Setting of the end positions

4.5.1. Automatic setup-mode, deletion and automatic setting of the end positions

in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in automatic set-
up-mode. The drive SEZ-RC is finding the end points in the upper and lower end position
automatically.
Important: A limit stop for the upper and lower end limit is necessary!
First the upper end limit has to be run-up to. From there move against the lower limit stop
without interruption, until the motor is automatically switched off.
Setting with
Setting with
switch
setting switch
or
Drive
Move the motor upwards with the UP or
DOWN button. The correct rotation direction
STOP
E
assignment will be carried out at the end of the
STOP
end position setting.
The motor moves against the upper stop and
stops automatically.
Continue to push the pushed button or push
one of the motion buttons again. The motor
automatically moves downwards.
The motor will reach the lower limit and stops
automatically.
The end positions are now set and the rotation
direction assignment is correct. Perform a test
run.