Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Setup-Mode, Deletion And Manual Setting Of The End Positions - Selve Sez-Rc Originalbetriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Setting of the end positions

4.5.3. Manual setup-mode, deletion and manual setting of the end positions

in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit stop
without interruption.
Setting with
Drive
setting switch
E
6 s
E
E
3 s
E
Auto-Stop
Press the E button of the setting switch for 6 seconds. The
motor will switch to manual setting mode. Both limit positions
already set will be deleted.
Move the motor to the lower end position with the UP or
DOWN button.
STOP
Press the E button for 3 seconds.
The correct rotation direction assignment will be carried out at
the end of the end position setting.
Run against the limit stop at the top without stopping; the
motor stops automatically.
STOP
The end positions are now set and the rotation direction assign-
ment is correct. Perform a test run.
48
Inhaltsverzeichnis
loading