Setting of the end positions
4. Setting of the end positions
4.1. Delivery status
In the SELVE delivery status no end positions or transmitters are programmed into the radio
motor! In this state, the motor can be operated in deadman's operation only. Safety functions
are deactivated at delivery and will only become active after both end positions are set.
In delivery status the SEZ-RC is in automatic programming mode. This will be signalized by a
short up and down movement when connected to mains.
4.2. Setup functions
The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109 or 291009) or with
• any standard switch (only in automatic mode) or with
• any standard commeo or iveo transmitter.
4.3. Mechanic requirements
When using the SEZ-RC the awning fabric will often be connected directly with the fabric
shaft.
Caution: When setting in automatic setting mode, a fixed, upper end limit has to exist. For
the setting in the automatic setting mode a limit (e.g. windowsill) for the lower switching-off
point has to be mounted.
4.4. Selection table for settings
Setup-mode/end positions in operation
Automatic setup- mode
bottom position, top stop/release*
Manual setup -mode
bottom position, top position
Manual setup- mode
bottom position, top stop/release*
* Both setting procedures are leading to the same result: bottom position: point, top position:
limit stop/relief
Setting switch
commeo radio iveo radio
4.5.1.
5.2.1.
(page 46)
(page 52)
4.5.2.
5.2.2.
(page 47)
(page 53)
4.5.3.
5.2.3.
(page 48)
(page 54)
44
6.1.1.
(page 57)
6.1.2.
(page 58)
6.1.3.
(page 59)