3. INSTALLATION

(1) Installing the air hose

1
Close
Open

(2) Raising and returning the sewing machine

DANGER :
1. If you find the sewing machine is too heavy to lift, the gas spring may have malfunctioned due to
outgassing.
Never lift the sewing machine in such a state since the machine can drop to pinch hands, fingers
and arms resulting in serious injury.
* Be sure to fully understand the standard of replacing time of the gas spring on p.56 and its re-
placement procedure on p.57 before putting the sewing machine into operation.
2. In order to prevent pinching of hands, fingers and arms that can result in a serious injury, be
sure to strictly observe the following when carrying out work.
2-1. Be sure to hold the rib on the bed periphery when holding the sewing machine.
2-2. Be sure to lock the hinge stopper to firmly secure the sewing machine in its raised position.
Fixing screw, left
■ Connecting the air hose
Connect the ar hose to the regulator usng
2
the hose band and the one-touch socket jont
suppled wth the machne.
■ Adjustment of air pressure
Open ar cock 1 , pull up and turn ar adjustment
knob 2 and adjust so that ar pressure ndcates
0.45 to 0.55 MPa. Then lower the knob and fix it.
* Close air cock 1 to expel air.
1) Remove the fxng screws, rght and left for
transportaton.
(8 mm wrench s suppled wth the machne.)
Fixing screw, right
Retain the screws since they are necessary
when moving the sewing machine. Be sure
to attach them when moving the sewing
machine.