EN
LASER LEVEL
6. Place the device to the opposite wall. Mark position of horizontal
line on the wall as B2.
7. Turn the instrument by 180° and mark position of horizontal line on
the opposite wall as A2.
8. Measure vertical distance between marks A1, A2 and B1, B2. If
distance between measured values exceeds 3 mm, please contact
service center.
12
12
CONDTROL SMART 2D Plus
5m
user manual