USER MANUAL

2.6.9 Auto Power Off

Choose Turn off Setting with the button 1 and mark with Button 2
CONFIRM. The +/- buttons can be used to select ON or OFF.
If ON is selected, the minutes (001min-040min) can be set with the button 1 .
Save 2 SAVE and leave the menu with 3 BACK.

2.7. Calibrate temperature

After changing the desoldering tool or the heating insert or soldering tip, it is
.
recommended to calibrate the temperature
Set the temperature of the soldering station to any
value (e.g. 300°C)
When the displayed value has stabilized, the
temperature must be measured at the soldering tip.
(e.g. with the measuring device QU191AD)
Long press buttons 1 and 3 at the same time.