If you tighten the screw to a measurement that is too large, the screw may become overstressed,
cracked, damaged, etc. Before starting a work, be sure to perform an evaluation to determine the
measurements of your tightening screws.
When using a torque above 30Nm for a long time, it is recommended to use it with a reaction arm.
When using a large torque of 60Nm or more, it is recommended to turn on the EPS operation to
prevent personnel from spraining their hands. If the EPS is not turned on, please use appropriate
reaction arm to ensure the safety of the operator and improve comfort during long-term work.
Fastening torque is affected by many factors such as the following
1. The way holding the tool or the material of the workpiece will affect torque.
2. Not using the correct size socket to fasten the screws。
3. Bolt:
Even if the torque coefficients and grades of bolts are the same, the allowable
tightening torque is different depending on the diameter.
Even if the diameter of the bolt is the same, the allowable locking torque is
different depending on its torque coefficient, grade and length.
different depending on its torque coefficient, grade and length.
NOTE
Strongly recommend to turn on EPS function if applied torque over 60Nm. This is to
prevent injury caused by reaction force from the high torque. In the case of not using EPS, operate with
mechanical arm or reaction arm instead.
Troubleshooting
Code
Description
E001
Over current
E002
Low Battery
E003
Battery
overheating
E004
Battery low
temp
E005
MOS high
temp.
E006
Electric short
E007
Motor stall
E008
Motor
overheating
E009
Strain gauge
fault
E010
Abnormal
memory
1English1
Troubleshooting
1. Electronic fault, Call service center
1. Change Battery
2. Electronic fault, Call service centre
1. Change Battery
2. Wait sometime for tool and battery to cool out.
3. Electronic fault, Call service centre
1. Change Battery
2. Sit battery in suggested temp., then reinstall.
3. Electronic fault, Call service centre
1. Sit tool in suggested temp to cool it.
2. Electronic fault, Call service centre
1. Electronic fault, Call service centre
1. Gearbox broken or electronic fault, call service center
1. Sit tool in suggested temp to cool it.
2. Electronic fault, Call service centre
1. Strain gauge broken or electronic fault, call service
centre
1. Electronic fault, Call service centre