9. Shift-down Speed
This screen indicates shift-down speed. Press
EDIT mode. Press
SAVE and EXIT.
Shift-down torque and shift-down speed are helpful to
improve precision especially in lower torque application.
Tool starts in free speed setting value and turns to shift
down speed setting value while shift down torque setting
value is reached. For example, the initial speed is 500
rpm and torque target is 10Nm. If user set shift-down
speed and shift-down torque as 200 rpm and 5 Nm, the
tool will start at 500 rpm, and go to 200 rpm when
torque is reached 5Nm and shut-off in 10Nm. User may
try to optimise shift-down torque and shift-down speed
to get better performance.
10. Gang Count
This screen indicates the gang count number of bolts to
be fastened per group or gang. The maximum is 1000.
Press
to enter EDIT mode. Press
Press
to SAVE and EXIT.
11. Torque Unit
This screen indicates the unit of torque displayed. 4
kinds of units, Nm, ft-lb, in-lb, kgf-cm, can be set. The
maximum is 1000. Press
/
to select. Press
12. Date& Time
This screen displays tool time in YYYY.MM.DD,
HH:MM:SS format. Press
/
/
/
to set. Press
1English1
/
/
/
to adjust. Press
/
to enter EDIT mode. Press
to SAVE and EXIT.
to enter EDIT mode. Press
to SAVE and EXIT.
English
-15-
to enter
to
/
/
to set.
-15
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rv2053-wr80Rv2053-wr120

Inhaltsverzeichnis