EN
General installation diagram
AUX 1
pH PUMP
N
L
Main screen and functions
1
2
3
4
pH
7.25
7.60
123
ClmV
725
750
27.2
FLOW
10
°C
12:15
OK
11
12
Control Connect
All in One
1) Wi-Fi status LED
9) Sensors (temperature and fl ow)
2) Statistics menu
10) Bluetooth connectivity
3) Confi guration menu
11) Home menu
4) Information menu
12) Relay status (R1out–R4out)
5) Relay menu
6) Alarm LED
7) pH
8) ORP
See complete manual for further
information on:
• pH and ClmV menu
• Relay menu (R1-R4)
Initial Start-Up
1. Make sure that the fi lter is clean and that there is no copper or iron in the water in the pool
or the installation.
2. Balance the pool water. This will enable more effi cient treatment with a lower concentra-
tion of free chlorine in the water and reduce the build-up of limescale in the pool.
3. If the pool is to be used immediately, chlorine treatment should be carried out. Initial dose:
2 mg/L trichloroisocyanuric acid.
See complete manual for further information on:
• Installation and calibration of pH, ORP and temperature sensors
• Maintenance of peristaltic pumps
Control panel
ORP
pH
F10E
pH
PH
ORP
ORP
COVER
Cl EXT
-
FLOW
+
-
UV
+
AUX 2
VSP
VSP
pH
ORP
5
6
7
pH setpoint
pH
ClmV
Sens
8
7.60
pH
7.25
9
7.60
123
ClmV
725
750
27.2
FLOW
°C
12:15
OK
Cl
2
pH
3 x 1.5 mm
2
230 Vac
Resistive load
max 10 A
AC1
2.3 kW
1 2
Inductive load
3 CV
AC3
Outlet
pH
ORP
Inlet
Choose language
7.25
123
pH
7.25
27.2
°C
7.60
123
ORP setpoint
ClmV
725
750
7.25
27.2
FLOW
°C
12:15
OK
123
27.2
°C
R1
TREATMENT AND PUMP CONTROL
PUMP AND TREATMENT
SYSTEM PROGRAM-
CONTROLLED
Blue
PUMP AND TREATMENT
SYSTEM ON
Green
PUMP AND TREATMENT
SYSTEM OFF
Red
Disinfection treatment, sensors,
ORP & pH
Pool water balance
The water must be maintained within the follow-
ing parameters:
• Total alkalinity between 60 and 120 mg/L (ppm)
• pH between 7.2 and 7.6
• Free chlorine between 0.5 and 2 mg/L (ppm)
• Chlorine stabiliser between 25 and 30 mg/L (ppm).
In pools that are exposed to strong sunshine or in-
tensively used, it is advisable to maintain a level of
25–30 mg/L of stabiliser (isocyanuric acid).
Check and maintain correct water balance
throughout the season.
Panel inlet and
outlet
stopcocks
1
2
3 x 1.5 mm
2
230 Vac
Resistive load
max 6.5A
AC1
1.5 kW
Inductive load
1/3 CV
AC7-B
N.B.: The red LED light on the control panel
signals an alarm.
/Confi g
/Confi g
pH
Language ENG
Screen
100
Screen
100
7.60
Language
ENG
Language
ENG
ENG
Sound
Sound
ClmV
725
Touch
Touch
750
FLOW
SAVE
12:15
OK
pH
ClmV
Sens
720
pH
7.60
ClmV
725
750
FLOW
12:15
OK
R2
R3
R4
EXTERNAL DEVICES CONTROL
RELAY PROGRAM-
CONTROLLED
Blue
ON
Green
OFF
Red