Setting the end positions and the relief

5.6
Setting the end positions and the relief
Important preliminary consideration:
Decide on a specific relief function before setting the end
positions (different combination options according to the
following statements):
This will save unnecessary setting effort!

5.6.1 Relief function for the end position(s)

If an end position is set to stop, an additional relief for the
roller shutter can be released.
Important
Activation of the relief function (in the versions B to D) takes
place in one work step when the end positions are pro-
grammed (see chapter 5.6.7 to chapter 5.6.9)!

5.6.2 Relief function at the upper stop

For variant C (see chapter 5.6.7)
and variant D (see chapter 5.6.8):
Activate relief function at the upper stop.
1
Move the blind to the upper stop position using the
assembly cable, then, while continuing to hold down
the [UP ▲] button, also press the [DOWN ▼] button
as instructed in ① (chapter 5.6.7 and 5.6.8) (simul-
taneously) and keep both buttons pressed until the
blind stops.
The relief function at the upper stop is activated.

5.6.3 Relief function at the lower stop

For version C (see chapter 5.6.8)
and version D (see chapter 5.6.9):
Activate relief function at the lower stop
1
Using the assembly cable, move the blind to the
lower stop, then, while holding down the [DOWN] but-
ton from instruction ③ (chapter 5.6.8 and 5.6.9), also
press the [UP] button (simultaneously) and keep both
buttons pressed until the blind stops.
The relief function at the lower stop is activated.
5.6.4 Changing / Deleting the limit positions
and deleting the discharge function
A change or deletion of a single end position is not possible.
This is always done in pairs (upper and lower end position
simultaneously).
By the deletion of the end positions and the adjustment of
the optional discharge function is lost.
Important
The roller shutter is adjusted only after a complete and
uninterrupted access and exit to the blind.
Changing / Deleting the end positions
1
From a middle blind position with the assembly cable,
push and hold both direction buttons (▲ and ▼) at
the same time until the drive briefly moves up and
down.
The deletion of the setting of end position is completed.
The end positions can be programmed again.

5.6.5 Four variants of end position settings

Four different combinations of end position settings are
possible. They must be selected sensibly according to the
technical requirements of the roller shutter.
End position settings
(4 versions)
A
Upper and lower end posi-
tion freely adjustable
B
Fixed upper limit stop /
lower end position freely
adjustable
C
Fixed upper and lower limit
stop
D
Upper end position freely
adjustable, fixed lower limit
stop
Fig. 7 Versions of the end position settings in the RolTop
5.6.6 Variant A: Upper and lower end position
Variant A:
Upper and lower end position freely adjustable
From a middle blind position with the assembly
cable, push the UP button ▲ until the roller shutter
has reached the desired end position.
The drive starts, stops briefly and then moves on
(while the UP button ▲ is pushed).
Correction is possible with the buttons ▲ and ▼ .
Press the AB button ▼ until the drive stops auto-
matically.
The upper end position has been set.
Press the AB button ▼ again until the roller shutter
has reached the desired lower end stop.
The drive starts, stops briefly and then moves on
(while the AB button ▼ is pushed).
Correction is possible with the buttons ▲ and ▼ .
Press the AUF button
automatically.
The lower end position has been set.
Setting of the end positions variant A is now complete.
Fig. 8 End position setting Variant A:
5.6.7 Variant B: Fixed upper limit stop / lower
Variant B: Fixed upper limit stop / lower end posi-
tion freely adjustable
From a middle blind position with the assembly
cable, push the UP button ▲ until the roller shutter
has reached the desired end position (run to the
upper stop).
The drive starts, stops briefly and then moves on
(while the UP button ▲ is pushed).
The drive switches off automatically when the upper
limit stop is reached.
Press the AB button ▼ until the drive stops auto-
matically.
The upper end position has been set.
Optional: Activation of the relief function for the
upper stop; see chapter 5.6.2
© elero GmbH
possible with
T-strap, tapes,
belt
T-strap, tapes,
belt, limit plugs,
angle bracket
Anti push-up device,
stiff shaft connector,
limit plugs, angle
bracket
Anti push-up device,
stiff shaft connector
freely adjustable
until the drive stops
end position freely adjustable
EN | 5
Inhaltsverzeichnis
loading