Technical data

Power supply ............................ 230V AC / 115V AC, 50/60 Hz, 1300 W
Working range ..........................  16-125mm
Protection / Protection class ..... I / IP20
Dimensions .............................. 500x200x65mm
Weight ...................................... 3,1 kg
3

Function of the unit

3.1

Overview (fig. A)

1
Isolated Handle
2
Flex with Plug
3
Pushbutton
4
"+" / "-" button
5
red diode "Stand by"
The handy pipe socket welding machines are designed fort he overlap welding of PE, PP and
PVDF plastic pipes and shaped pieces in a workshop and on sites.
There are two methods of welding: type A und type B.
Using method A the pipe is used without peeling, it is simply chamfered.
Using method B the pipe must be peeled to a certain length and then chamfered.
The ROTHENBERGER heating jacks (8) and -arbours (9) are designed in form A and are
marked accordingly on the uncoated rear.
3.2

Operating instructions

The Heating Element must be used by well trained and autorized operators only!
3.2.1

Putting into operation

Please read the operating- and safety-instructions attentively before putting the
heating element into operation!
Do not use the heating element in explosive environments or bring it into
contact with easily flammable materials!
 Fit the corresponding heating jacks (8) and heating arbours (9). Secure heating arbour (9)
with counter pin (10) and thighten the screw M6x40 with allen key (s.fig. A).
 Insert the heating element with the mounting groove in a table clamp (no.: 55540) or floor
stand (no.: 55539).
 Connect power plug to the power supply stated on the type plate.
The red "Stand by" diode on the heating element lights up, which means: voltage is being
applied. Switch on the heating element on the hand grip using the large press-button (lights up
green) and set the desired temperature using the "+" or "-" button (160°C to 285°C / 320°F to
545°F).
Heating is displayed on the hand grip by the yellow diode. Horizontal bars also appear on the
temperature indicator. The yellow diode goes out shortly before reaching the set nominal
temperature (tolerance +/-3°C / 5.4°F) and the green one lights up. The heating element is
usable after a further 10 minutes. Note: upon first reaching the nominal temperature the set
value can be exceeded for short time.
12
6
temperature indicator
7
Heating plate
8
Heating jack
9
Heating arbours
10
Counter pin