Herunterladen Inhalt Inhalt Diese Seite drucken

Variant D: Upper End Position Freely; Adjustable, Fixed Lower Limit Stop; Placement Of Roller Blind Slats; Travel Profiles - Elero Rolmotion M Nutzungsinformation

Rollladenantrieb
Vorschau ausblenden Andere Handbücher für RolMotion M:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

End position settings | Travel profiles
5.6.6 Variant D: U pper end position freely
adjustable, fixed lower limit stop

Variant D: Upper end position freely

adjustable, fixed lower limit stop
Starting from a central blind position, press the [UP
▲] button with the assembly cable or a programmed
transmitter until the blind reaches the desired upper
end position.
The drive begins to travel, briefly stops and travels
further (for as long as the button remains pressed).
You can make corrections using the [UP ▲]
and [DOWN/CLOSE ▼] buttons.
Press the [DOWN/CLOSE ▼] button until the drive
stops automatically.
The upper end position has been set.
Press the [DOWN/CLOSE ▼] button again until the
blind has reached the desired end position (travels
to the lower limit stop).
The drive begins to travel, briefly stops and travels
further (for as long as the [DOWN/CLOSE ▼] button
remains pressed).
The drive switches off automatically when the lower
limit stop is reached.
Press the [UP ▲] button until the drive stops
automatically.
By default, the lower end position has been set.
Non-standard setting for the placement of the blind
slats at the lower end position: See chapter 5.7.
Adjustment of the variant D end position is complete.
5.7

Placement of roller blind slats

For slow lowering of the roller shutter bars, a standard
travel path is set after programming the end positions.
It is possible to change this position when the end positions
have been programmed as follows:
• After the blind starts to rise from the lower end position,
hold down the [UP ▲] button until the drive starts to move
further up after approx. 2 seconds. As soon as the lowest
blind slat is raised from the lower limit stop, release the
[UP ▲] button. This is now the position from which slow
downward travel commences.
6
Travel profiles
The RolMotion M drive has the two travel profiles default
mode and whisper mode.
6.1
Travel profile default mode
When travelling at high speed, only the roller blind slats are
lowered slowly.
This travel is triggered by simply turning on the wall switch/
button.
6.2
Travel profile whisper mode
Travel at slow speed along the entire travel path.
This travel is actuated by "double-clicking" at power up
(On - Off - On) or during travel by switching off and on again
in the same direction of travel. The duration of the switched-
off state must be more than one second.
To change to the travel profile default mode, the drive must
be switched off for one second.
The travel profile whisper mode is not available during the
"Setting the end positions" operation.
6.3
Changing the travel profile
The user can decide whether the default mode or the
whisper mode is to be used for a simple keystroke or an
automatic run command (e.g. from a timer). It the key is
pressed twice, the other travel profile is activated.
Requirements:
• Endpositions are learned
• Changing the travel profile is only possible on upper or
lower limit stop.
• Direction switch ([button UP ▲] or [button DOWN/
CLOSE ▼]) mus be de-energised for at least 2 seconds.
• The other - currently not active - travel profile is activated
by pressing one of the two following button sequences:
►On upper end position
[UP ▲] 1 s, [UP ▲] 1 s, [UP ▲] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 3 s.
►On lower end position
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[UP ▲] 1 s, [UP ▲] 1 s, [UP ▲] 1 s.
the pauses between the individual keystrokes must not be
longer than 1 s.
Important
For wired control units the run command [button UP ▲] or
[button DOWN/CLOSE ▼] must be aborted manually as
follows:
►On upper end position
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 3 s.
►On lower end position
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 3 s.
7

Troubleshooting

Problem /
Error
• Drive stops
during travel
• Drive stops
after short time
• Drive moves
in the opposite
direction
without a
new travel
command and
stops after a
short travel
© elero GmbH
Possible
Remedial
cause
action
• End positions
• Setting end
are not set
positions
• End position
• Set second
programmed
end position
• Stiff blind
• Check the
smooth run-
ning of the
blind
• Obstacle in the
• Remove
travel area
obstacle
EN | 7
Inhaltsverzeichnis
loading

Inhaltsverzeichnis