5.Slide Belt Guard pack into place above Drain Cleaner drum. Tighten Belt
Guard Knob to lock Belt Guard back into place.
WARNING! Do not operate the Drain Cleaner without the Belt Guard in
place.
1.Remove old cable by pulling cable completely out. Separate cable from drum-
connecting cable.
2.Connect new cable to drum-connecting cable and feed cable back into drum.
General Cleaning, Maintenance, and Lubrication
1. BEFORE EACH USE, inspect the general condition of the tool. Check for:
• loose hardware,
• misalignment or binding of moving parts,
• cracked or broken parts,
• damaged electrical wiring, and
• any other condition that may affect its safe operation.
2. AFTER USE, wipe external surfaces of the tool with clean cloth.
3. WARNING! If the supply cord of this power tool is damaged, it must be
replaced only by a qualified service technician.
Troubleshooting
Problem
1. The motor may have
been shut off by its internal
Motor shuts off
thermal protection switch,
During use.
or auto reset breaker.
2. GFCI breaker tripped
1. Too much force on the
cable.
2. Too much slack
between Drain Cleaner and
Cable inks,
drainpipe inlet.
twists, or
3. Cable used is wrong size
breaks.
for drain pipe.
Probable Cause(s)
1. Turn motor off. Allow motor to cool off
completely before restarting and stay clear
of cable when turning motor back on.
2. Make sure all electrical components are
dry and all insulation is in good repair.
Press reset button. If GFCI trips again,
have machine serviced by qualified
electrician before further use.
1. Do not force cable. Let cutter do the
work.
2. Move Drain Cleaner to within two feet of
drainpipe inlet.
3. Change cable size.
4. Clean and oil cable regularly.
- 22 -