Herunterladen Inhalt Inhalt Diese Seite drucken

VEVOR SD308 Bedienungsanleitung Seite 10

Automobil-nebelmaschine lecksucher
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 29
MODE) to start working; only after this mode is activated can the smoke mode
(SMOKE MODE) potentially start working.
6. After pressing the air mode switch (AIR MODE) to start working, pay attention to
the indication of the pressure gauge. If the indication exceeds 15PSI and the flow
meter float remains at the bottom without movement, it indicates no leakage. If the
pressure gauge pointer rises slowly and the flow meter continuously indicates
airflow entering (float rising), check whether the access pipeline is properly
connected. Once the connection is confirmed, it indicates a leak in the tested
system, and you can then press the smoke mode (SMOKE MODE) switch.
7. Press the smoke mode (SMOKE MODE) switch to start the smoke. In this mode,
depending on the vehicle model, it will take approximately 1-3 minutes to fill the
internal system with smoke. Begin checking for leak faults during this process. If
during this process, the smoke oil in the detector is insufficient or if the detector
operates continuously for too long (approximately 5 to 9 minutes depending on the
specific working environment), causing overheating, the overheat protection
indicator light
will illuminate, and the operation will pause until the
temperature returns to the normal range, at which point the detector will resume
operation.
8. During use, if you encounter recoil force, the pressure gauge will show a sudden
abnormality, and the smoke will stop for 1-3 seconds. This is non-continuous and
is normal. After the inspection is complete, unplug the power cord and store the
accessories for next use. The main body of the air inlet adapter is made of rubber,
please avoid contact with corrosive liquids such as gasoline.
9. Use of Universal Adapter: Place the universal adapter at the opening pipe which
needs to be sealed, tighten the metal knob on the bellows clockwise. Then, press
the airbag to be inflating it seals (the maximum diameter of the airbag should not
exceed 10CM). Insert the smoke tube into the airbag hose, causing smoke to enter
the detection pipeline, After the inspection is completed, loosen the metal knob by
turning it to the left to quickly release the air and remove the airbag.
10. When using accessories for leak testing, such as Pipe adapter, EVAP adapter,
or Cone adapters, insert the smoke tube into the hose port causing smoke to enter
the detection pipeline, then seal the corresponding pipe opening on the other end.
- 10 -

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis