Screen Messages
Display Message
Excess current
No oranges
Memory initiated
Calibration
Out of service
Eeprom
Out of range
Keyboard error (error 1)
Juice tray picture flashing
*The message: "Keyboard error" may not appear on the display as there is no communication between the CPU
and the keyboard panel
Cause
The maximum electrical
consumption level has been
exceeded for at least one
second.
The motor remains on for
two minutes detecting any
squeezing.
A memory error has been
detected.
An incorrect calibration value
has been detected.
The counter has reached zero.
Error detected in EEPROM
memory.
The input power voltage is less
than 80V or greater than 260V.
No communication with the
keyboard (Internal fault).
Check the juice tray and front
cover are placed correctly.
Correction
Turn off at mains and turn back
on again.
Put oranges back in feeder
again without and press ON.
Contact your technical service.
Calibrate.
Modify the discounter value as
indicated in page 21 or move
on to counter function entering
PARTIAL COUNTER and
pressing ON.
Contact your technical service.
Contact your technical service.
Contact your technical service.
Place the tray and cover in its
correct position as Fig. 4. If
the picture does not disappear,
contact your technical service.